KD-208A
+
  • KD-208A

KD-208A


With LCD display

Response time: 27±3PPM>120min

                           55±5PPM60-90min

                           110±10PPM10-40min

                           330±30PPM<3min

Concentration range displayed: 10-550PPM

Power source: DC3V, 2PCS AA batteries

Battery service life: 3 years

Static working current: <35uA

Alarm current: <70mA

Alarm sound: >85dB(3M distance)

Dimension: 120*74*31mm

Weight: 125g

EN50291-1: 2018


BSCI
ROHS
bsi
CE
Q
noise

// Detailed //

Kingdun KD-208A Wireless Carbon Monoxide Alarm

 

Your Smart Home Guardian Against Silent Killers

The Kingdun KD-208A is a cutting-edge carbon monoxide (CO) detector designed to safeguard your home with advanced sensing technology and intuitive operation. Compliant with EN 50291-1:2018 standards, this alarm offers early detection, multiple alert modes, and a 10-year lifespan, ensuring reliable protection for your family.

 

Feature Description
Detection Technology Electrochemical sensor with high accuracy (±10–15% depending on concentration)
Alarm Types High-concentration alarm, low-concentration warning, fault alerts, battery low
Display Digital LCD showing CO levels (10–550 PPM), battery status, and error codes
Power Source 2x AA LR6 alkaline batteries (3-year lifespan)
Response Time Meets EN 50291-1:2018 standards (e.g., 3 minutes at 330 PPM)
Audible Alarm >85 dB at 3 meters
Dimensions 120 × 74 × 31 mm / Weight: 125g

 

Key Functions

Multi-Level Alerts

High CO Alarm: Red light flashes 5 times with 5 beeps (3 cycles/10 seconds) when CO exceeds dangerous levels.

Low CO Warning: Slower 4-flash/4-beep pattern every 3–5 minutes for prolonged exposure to 30–40 PPM.

Fault/Battery Alerts: Yellow light with beeps for sensor issues, low voltage (<2.3V), or end-of-life (10 years).

Smart Features

Silent Mode: Temporarily mute the alarm (CO <200 PPM) while maintaining visual alerts.

Self-Test: Press the TEST button weekly to verify sensor, buzzer, and lights.

Auto Recovery: Stops alarming automatically when CO drops below 40 PPM.

Safety Design

Non-removable Sensor: Factory-calibrated to prevent unauthorized tampering.

Battery Pin Lock: Prevents installation without correctly inserted batteries.

 

Installation Guide

Ideal Locations: Bedrooms, living areas, and near fuel-burning appliances (keep 1.5m from corners/furniture).

Avoid: Kitchens, garages (near vehicle exhaust), vents, or damp/high-temperature zones.

Steps:

Secure the mounting plate (height >1.5m, 0.3m from ceiling).

Insert 2 AA batteries and test functionality.

Slide the alarm onto the plate until it clicks.

 

Maintenance Tips

Monthly Cleaning: Use a vacuum or damp cloth; avoid chemicals.

Battery Replacement: Replace immediately when low battery warning activates (lasts 30 days post-warning).

Gas Sensitivity: Keep away from aerosols, alcohol, or solvents to prevent false alarms.

 

Emergency Protocol

Alarm Sounds:

Evacuate to fresh air, turn off fuel appliances, and call emergency services.

Do not re-enter until the alarm stops and CO levels are confirmed safe.

Low CO Warning:

Ventilate the area and reduce exposure, especially for children, pregnant individuals, or the elderly.

 

Technical Specifications

Parameter Specification
Gas Detected Carbon monoxide (CO)
Operating Range -10°C to +45°C / 0–93% humidity
Accuracy 30 PPM ±10 PPM; 50 PPM ±10 PPM; 100–300 PPM ±15%
Alarm Silence Duration Up to 10 minutes (CO <200 PPM)
Service Life 10 years (end-of-life warning displays "End")

 

 

Why Choose Kingdun KD-208A?

 

Certified Safety: Meets European EN 50291-1:2018 standards.

User-Friendly: Simple installation, intuitive LCD, and one-button testing.

Long-Term Reliability: 3-year battery life and 10-year sensor durability.

 

Protect your home from invisible threats. The Kingdun KD-208A is your trusted partner in ensuring peace of mind.

 

 
 

Product Specifications

Parameter Description
Gas Detected Carbon monoxide
Dimension 120 × 74 × 31 mm
Weight 125 g
Power Source Two AA LR6 1.5V alkaline batteries (Pairdeer/Mustang brand)
Low Battery Warning Activated at voltage < 2.3V; unit remains operational for 30 days post-warning
Battery Service Life 3 years
Operating Temperature -10°C to +45°C
Humidity Range 0–93% relative humidity
Quiescent Current <35 μA
Alarm Current <70 mA
Audible Alarm Volume >85 dB (measured 3 meters away)
Displayed Concentration Range 10–550 PPM
Digital Display Accuracy - A) 30 PPM ±10 PPM
- B) 50 PPM ±10 PPM
- C) 100 PPM ±15%
- D) 300 PPM ±15%

Carbon Monoxide Alarm

10Y Battery Smoke Alarm

Wireless Online Smoke Alarm

Mini Smoke Alarm With Long Life Battery

Classic Smoke Alarm

Water & Heat & Gas Alarm

WiFi Smart Home Alarm System

Intelligent Gas Cut Off Valve

Related products

KD-128A

Power source: DC9V(CR2450 3X3V) Quiescent currents: ≤10uA Alarm current: ≤20mA Alarming decibel: ≥85dB/3m Low battery signal Push to test No hush feature Minisize: (diameter)72x37mm EN 14604:2005/AC:2008

BSCI
ROHS
FIRE
CE
Q
noise
ANPI

Learn more >

KD-127D

Power Source: 9V battery Quiescent current: ≤12uA Alarm current: ≤20mA Alarmdecibel: ≥85dB/3m Low battery signa Push to test Hush feature Size: (diameter)101x34mm EN 14604:2005/AC:2008

BSCI
ROHS
FIRE
CE
Q
noise
e
ANPI
UKCA

Learn more >

LM-109C

Power source: DC 3V(build-in lithium battery) Quiescent current: ≤2uA Alarm current: ≤120mA Alarming Decibel: ≥85dB/3m Low battery signal Push to test Hush feature Mini size: (diameter)67x47mm EN 14604:2005/AC:2008

BSCI
ROHS
LPCB
FIRE
VDS
CE
Q
CELL
noise
UKCA

Learn more >

LM-109E

Power source: DC 3V(build-in lithium battery) Quiescent current: ≤2uA Alarm current: ≤120mA Alarming Decibel: ≥85dB/3m Low battery signal Push to test Hush feature Mini size: (diameter)67x47mm EN 14604:2005/AC:2008

BSCI
ROHS
LPCB
FIRE
VDS
CE
Q
CELL
noise
UKCA

Learn more >

LM-109G

Power source: DC 3V(build-in lithium battery) Quiescent current: ≤2uA Alarm current: ≤120mA Alarming Decibel: ≥85dB/3m Low battery signal Push to test Hush feature Mini size: (diameter)67x47mm EN 14604:2005/AC:2008

BSCI
ROHS
LPCB
FIRE
VDS
CE
Q
CELL
noise
UKCA

Learn more >

LM-109D

Power source: DC 3V(build-in lithium battery) Quiescent current: ≤2uA Alarm current: ≤120mA Alarming Decibel: ≥85dB/3m Low battery signal Push to test Hush feature Mini size: (diameter)67x47mm EN 14604:2005/AC:2008

BSCI
ROHS
LPCB
FIRE
VDS
CE
Q
CELL
noise
UKCA