KD-127D
With replaceable battery
Power Source: 9V battery
Quiescent current: ≤12uA
Alarm current: ≤20mA
Alarmdecibel: ≥85dB/3m
Low battery signa
Push to test
Hush feature
Size: (diameter)101x34mm
EN 14604:2005/AC:2008
// Detailed //
The instruction of smoke alarm devices
1. Shape and size
2. Technical parameter
Working Voltage:9V DC(re-commanded battery:6F22,GP 1604S,GP 1604A,
PAIRDEER 6F22,OSEL 6LR61,PAIRDEER 6LR61,FORTE ER9V,
EVE CR-9V,ULTRALIFE ULVL-J,FANSO ER9V)
Current: Quiescent Current:≤12uA
Alarming Current: ≤ 20mA
Alarming Decibel:≥85dB/3m
HUSH Status:LED flashes every 10S
Standby status:LED flashes every 43S
Low battery status: special low battery beep around every 43S
LED Indicator:LED(Red)
Low voltage Alarming:≤7.35V
Working Temperature:-10℃~+40℃
Working Humidity:≤95%RH(no water gel)
3. Test and before installation:
Note:If the battery is not installed correctly, the detector will not work and maybe destroyed.
If the detector operates smoothly, the Red LED will flash once in about 43S.
Take the product out of the packaging,take off the installation base from the product via rotating the product on the anti-clockwise direction.
Take out the 9V battery from battery compartment, remove the insulation film from the battery, connect the battery to battery buckle and put it back to battery compartment.
Depress(keep depressing and release till finish the testing) the test/hush button,the RED LED flashes quickly and in the meanwhile the detector sounds, which means the the detector works well. At the same time the product goes into low sensitivity detection mode, round 10 minutes later the product goes into standard sensitivity detection mode again.
4. Installation
(1) Choose a right place to install the smoke alarm.
The alarm may not be mounted In:
A) a room in which the temperature can reach below -10°C and above 40°C.
B) in damp spaces
C) just in front of doors or windows and not near a ventilator or radiator
D) Maintain a distance of at least 50 cm from fluorescent lights or low-energy bulb.
(2) Fix two plastic screw base into ceiling according to installation hole position of smoke alarm base
(3) Fix the installation base on ceiling via screws at pre-installed screw base.
(4) Make sure the battery is installed and well connected to the smoke alarm (you may use the test button function to check) and fasten the smoke alarm to pre-installed base via clockwise rotation.
(5) Use the test button again to make a final check.
Carbon Monoxide Alarm
10Y Battery Smoke Alarm
Wireless Online Smoke Alarm
Mini Smoke Alarm With Long Life Battery
Classic Smoke Alarm
Water & Heat & Gas Alarm
WiFi Smart Home Alarm System
Intelligent Gas Cut Off Valve
Related products
Power source: DC9V(CR2450 3X3V) Quiescent currents: ≤10uA Alarm current: ≤20mA Alarming decibel: ≥85dB/3m Low battery signal Push to test No hush feature Minisize: (diameter)72x37mm EN 14604:2005/AC:2008
Power Source: 9V battery Quiescent current: ≤12uA Alarm current: ≤20mA Alarmdecibel: ≥85dB/3m Low battery signa Push to test Hush feature Size: (diameter)101x34mm EN 14604:2005/AC:2008
Power source: DC 3V(build-in lithium battery) Quiescent current: ≤2uA Alarm current: ≤120mA Alarming Decibel: ≥85dB/3m Low battery signal Push to test Hush feature Mini size: (diameter)67x47mm EN 14604:2005/AC:2008
Power source: DC 3V(build-in lithium battery) Quiescent current: ≤2uA Alarm current: ≤120mA Alarming Decibel: ≥85dB/3m Low battery signal Push to test Hush feature Mini size: (diameter)67x47mm EN 14604:2005/AC:2008
Power source: DC 3V(build-in lithium battery) Quiescent current: ≤2uA Alarm current: ≤120mA Alarming Decibel: ≥85dB/3m Low battery signal Push to test Hush feature Mini size: (diameter)67x47mm EN 14604:2005/AC:2008
Power source: DC 3V(build-in lithium battery) Quiescent current: ≤2uA Alarm current: ≤120mA Alarming Decibel: ≥85dB/3m Low battery signal Push to test Hush feature Mini size: (diameter)67x47mm EN 14604:2005/AC:2008
You can also leave us a message.
Our customer service department can provide you with information and answer your questions, and you can also visit the FAQ.